By GR Reddy

ISBN-10: 8180616568

ISBN-13: 9788180616563

Fresh booklet in ideal Condition.Fast delivery with monitoring quantity.

Show description

Read or Download A Visual Evaluation with Automate Devices PDF

Similar ophthalmology books

Minimizing Incisions and Maximizing Outcomes in Cataract by I. Howard Fine, Jorge Alio, Mark Packer (auth.), Jorge L. PDF

Many ophthalmologists are within the transition from the conventional cataract surgical procedure strategy to the hot minimally incision cataract surgical procedure (MICS) approach. they're within the want of up to date details on tips on how to make this transition easily. during this booklet, world-renowned opinion leaders current up to date info at the new and fast-developing tendencies in cataract surgical procedure.

Get Clinical Atlas of Canine and Feline Ophthalmic Disease PDF

Medical Atlas of canines and pussycat Ophthalmic sickness offers an image-rich source for diagnosing and treating ophthalmic stipulations in medical perform. provides greater than six hundred fine quality colour pictures depicting in general encountered ocular stipulations in canine and cats comprises a number of photos for every affliction to teach various shows geared up for simple reference, masking the main in most cases encountered stipulations first Designed for day-by-day use within the busy scientific environment, permitting practitioners to speedy locate and examine photographs as they see situations presents a concise precis of the main clinically proper info on diagnosing and handling ophthalmic ailment

Download PDF by Hejtmancik, J. Fielding; Nickerson, John M: Molecular biology of eye disease

This quantity of development in Molecular Biology and Translational technological know-how specializes in the molecular biology of eye illness. Contributions from top experts Informs and updates on the entire newest advancements within the box

Extra resources for A Visual Evaluation with Automate Devices

Example text

MEAN DEVIATION The mean deviation index signifies average overall severity of field loss. In principle, it is the average of all the numbers shown in the total deviation plot except the two points nearer to the blind spot. The deviation from normal at each point is weighed according to the variance of the normal values at that location, Thus points with low variance-that is, closer to fixation-affect the MD value more than eccentric points, which have a higher variance. The mean deviation is expressed in dB units with P value.

24-2 SITA FAST - 5 MINUTES Please see pages 63- 69 for further details on the threshold testing strategies. 26 A VISUAL FIELD EVALUATION WITH AUTOMATED DEVICES IMPORTANT THRESHOLD TESTS TO DETECT GLAUCOMA FIELD DEFECTS Now, we know the available point patterns and the testing strategies. Whenever we ask for a visual field test we have to specify the point pattern and the testing strategy. The usual available central threshold test point patterns are as follows: 30-2 central field, 24-2 central field, 10-2 central field, macular program and nasal step.

The distance between each test point is 2°. The test points straddle the horizontal and vertical axes. The most important point is to be noted in the 10-2 field is, 2° resolution. Because the test points straddle the horizontal and vertical axes, the innermost points are only one degree from the fixation spot. So, only one degree of bare area is left surrounding the fixation spot. From this we understand, most of the central space surrounding the fixation spot is tested in 10-2 field. Hence it became the test of choice in all advanced cases of glaucoma to know about the macular status.

Download PDF sample

A Visual Evaluation with Automate Devices by GR Reddy


by Anthony
4.3

Rated 4.41 of 5 – based on 25 votes